| Add | CATALOG | CFE CAT. | A | B | C | D | Ø1 | Ø2 | TORQUE | RANGE | MECHANICAL STRENGTH KN — BODY | MECHANICAL STRENGTH KN — EYE | MECHANICAL STRENGTH KN — SLIP |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PRA-88 | RAL-8 | 250 | 51 | 28 | 27 | 15.9 | 12.7 | 54.2 Nm | 7.8 - 22.3 | 44 | 31 | 37 | |
| PRA-51 | RAL-6 | 196 | 38 | 29 | 18 | 15.9 | 9.5 | 27.1 Nm | 4.5 - 13.0 | 31 | N/A | N/A |
Products · Distribution
Distribution Connectors, Clamps & Fittings
Partalum compression-type distribution clamps and connectors are made of aluminum, bronze and copper for distribution networks of up to 35 KV and for grounding, referenced to the CFE catalog. The line covers connection, tap/branch, splice and conductor grounding.
Catalog · 19 products
Full breakdown of Conectores, Grapas y Herrajes de Distribución.
Each product with its render, catalog designation, standard, material and selection table by conductor — taken from the Partalum technical catalog.
Click the + to add products to your quote.
| Add | CATALOG | CFE CAT. | A | B | C | D | Ø1 | Ø2 | TORQUE | Ø PIN | CLAMP | MIN RANGE | MAX RANGE | ACSR |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PPA-46 | PAL-4 | 98 | 98 | 24 | 17.4 | 17.5 | 9.5 | 40 Nm | 15.9 | 2 | 4.5 | 14.3 | 6 - 4/0 | |
| PPA-86 | PAL-8 | 167 | 185 | 25 | 24 | 17.5 | 12.7 | 90 Nm | 15.9 | 2 | 7.6 | 18.3 | 3/0 - 336 | |
| PPA-112 | PAL-13 | 167 | 225 | 25 | 26 | 17.5 | 12.7 | 90 Nm | 15.9 | 4 | 13.2 | 22.3 | 3/0 - 477 | |
| PPA-130 | PAL-19 | 368 | 330 | 30 | 43 | 21.5 | 15.9 | 100 Nm | 19.0 | 5 | 19.1 | 34 | 397 - 1113 |
| Add | CATALOG | A | B | C | D | Ø1 | Ø2 | Ø PIN | TORQUE | CONDUCTOR RANGE |
|---|---|---|---|---|---|---|---|---|---|---|
| PPB-112 | 290 | 200 | 65 | 26 | 16 | 12.7 | 15.9 | 80 NM | 4/0 - 500 MCM | |
| PPB-130 | 320 | 260 | 60 | 43 | 19 | 15.8 | 19.0 | 100 NM | 500 - 1000 MCM |
| Add | CATALOG | CFE CAT. | A | B | C | D | Ø1 | Ø2 | MIN RANGE | MAX RANGE | MECHANICAL STRENGTH | ACSR RANGE |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PAS-62 | SAL-6 | 180 | 62 | 20.6 | 15 | 15.9 | 12.7 | 6.4 | 15.0 | 80 KN | 1/0 | |
| PAS-104 | SAL-13 | 192 | 64 | 30 | 28 | 15.9 | 12.7 | 12.7 | 26.4 | 111 KN | 266-477 | |
| PAS-139 | SAL-23 | 231 | 82 | 41 | 38 | 15.9 | 12.7 | 22.8 | 35.3 | 111 KN | 795-1113 |
| Add | CATALOG | A | B | C | Ø1 | Ø2 | MIN RANGE | MAX RANGE |
|---|---|---|---|---|---|---|---|---|
| PBS-139 | 225 | 75 | 36.9 | 15.9 | 12.7 | 22.8 | 35.3 | |
| PBS-104 | 192 | 64 | 30 | 15.9 | 12.7 | 12.7 | 26.4 |
| Add | CATALOG | CFE SHORT DESCRIPTION | A | B | C | MIN MAIN ACSR (mm²) | MIN MAIN ACSR (cond.) | MIN MAIN COPPER (mm²) | MIN MAIN COPPER (cond.) | MAX MAIN ACSR (mm²) | MAX MAIN ACSR (cond.) | MAX MAIN COPPER (mm²) | MAX MAIN COPPER (cond.) | MIN TAP ACSR (mm²) | MIN TAP ACSR (cond.) | MIN TAP COPPER (mm²) | MIN TAP COPPER (cond.) | MAX TAP ACSR (mm²) | MAX TAP ACSR (cond.) | MAX TAP COPPER (mm²) | MAX TAP COPPER (cond.) | TORQUE |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PGPU-336 | CONECTOR U 336 | 105 | 73 | 12.7 | 67.4 | 2/0 | 85.01 | 3/0 | 241.7 | 477 | 202.7 | 400 | 67.4 | 2/0 | 85.01 | 3/0 | 241.7 | 477 | 202.7 | 400 | 55 Nm | |
| PGPU-795 | CONECTOR U 795 | 117 | 85 | 16 | 170.5 | 336.4 | 202.7 | 400 | 402.8 | 795 | 432.7 | 900 | 170.2 | 336.4 | 202.7 | 400 | 402.8 | 795 | 432.7 | 900 | 76 Nm | |
| PGPU-1113 | CONECTOR U 1113 | 165 | 97 | 16 | 402.8 | 795 | 456.0 | 900 | 563.9 | 1113 | 506.7 | 1000 | 402.8 | 795 | 456.0 | 900 | 563.9 | 1113 | 506.7 | 1000 | 76 Nm |
| Add | CATALOG | CFE SHORT DESCRIPTION | A | B | C | D | MAIN RANGE | ACSR | ALUMINUM OR COPPER | TAP RANGE | ACSR | ALUMINUM OR COPPER |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PHA-C00 | CDP 4-6 / 4-6 | 38 | 44 | 8.5 | 8.5 | 4.1 - 6.4 | 6 - 2 | 6 - 2 | 4.1 - 6.4 | 6 - 2 | 6 - 2 | |
| PHA-C01 | CDP 7-10 / 4-6 | 40 | 49.1 | 10.8 | 8.9 | 7.1 - 10.1 | 3 - 1/0 | 2 - 2/0 | 3.9 - 8.0 | 8 - 2 | 6 - 2 | |
| PHA-C02 | CDP 7-10 / 7-10 | 47.8 | 60 | 12.3 | 11.8 | 7.1 - 11.3 | 3 - 2/0 | 3 - 3/0 | 7.1 - 11.3 | 3 - 2/0 | 2 - 3/0 | |
| PHA-C03 | CDP 11-12 / 4-6 | 47.8 | 58.4 | 14.8 | 8.8 | 10.1 - 12.8 | 1/0 - 3/0 | 2/0 - 3/0 | 3.9 - 8.0 | 8 - 2 | 6 - 1 | |
| PHA-C04 | CDP 11-12 / 7-10 | 47.8 | 60 | 14.7 | 10.7 | 10.1 - 14.3 | 1/0 - 4/0 | 2/0 - 4/0 | 7.1 - 10.1 | 3 - 1/0 | 2 - 2/0 | |
| PHA-C05 | CDP 11-12 / 11-12 | 63.5 | 51 | 15 | 15 | 12.8 - 14.3 | 3/0 - 4/0 | 3/0 - 4/0 | 12.8 - 14.3 | 3/0 - 4/0 | 3/0 - 4/0 |
| Add | CATALOG | CFE CAT. | A | B | C | D | Ø1 | Ø2 | MAIN RANGE | ACSR | TAP RANGE | ACSR |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PLA-54 | CD9 9-12/4-8 | 64 | 63 | 14 | 27 | 20 | 12 | 9.3 - 12.8 | 2 - 3/0 | 4.1 - 8.0 | 8 - 1/0 | |
| PLA-66 | CD9 9-12/9-12 | 70 | 69 | 15 | 28 | 24 | 16 | 9.3 - 12.8 | 2 - 4/0 | 9.3 - 12.8 | 2 - 4/0 | |
| PLA-336-10 | CD9 14-22/14-8 | 92 | 100 | 26 | 33 | 21 | 12 | 14.9 - 22.4 | 4/0 - 477 | 4.1 - 8.0 | 8 - 1/0 | |
| PLA-336-40 | CD9 14-22/9-12 | 92 | 105 | 26 | 33 | 24 | 16 | 14.9 - 22.4 | 4/0 - 477 | 9.3 - 12.8 | 2 - 4/0 | |
| PLA-477-40 | CD9 14-22/14-22 | 92 | 130 | 26 | 33 | 30.5 | 22.4 | 14.9 - 22.4 | 4/0 - 477 | 14.9 - 22.4 | 4/0 - 477 |
| Add | CATALOG | CFE SHORT DESCRIPTION | A | B | Ø1 | Ø2 | MIN RANGE | MAX RANGE | ACSR |
|---|---|---|---|---|---|---|---|---|---|
| PMT-44 | CRU 10 (1/0) | 50 | 24 | 18.3 | 10.4 | 9.3 | 10.1 | 8 - 1/0 | |
| PMT-66 | CRU 13 (3/0) | 63 | 31 | 23 | 15.8 | 11.9 | 13.2 | 4 - 3/0 | |
| PMT-66-40 | CRU 14 (4/0) | 76 | 37 | 23 | 15.8 | 11.9 | 14.3 | 4 - 4/0 | |
| PMT-77 | CRU 16 (266) | 127 | 63 | 30.4 | 20.5 | 14.9 | 18.8 | 4/0 - 336 | |
| PMT-77 | CRU 18 (336) | 127 | 63 | 30.4 | 20.5 | 16.9 | 18.8 | 4/0 - 336 | |
| PMT-88 | CRU 22 (477) | 127 | 63 | 31.5 | 23.5 | 20.1 | 22.4 | 4/0 - 477 |
| Add | CATALOG | CFE CAT. | A | B | Ø1 | Ø2 | MIN RANGE | MAX RANGE | ACSR |
|---|---|---|---|---|---|---|---|---|---|
| PPT-44R | N/A | 124 | 62 | 20.7 | 11.3 | 8.0 | 11.3 | 2 - 1/0 | |
| PPT-61R | N/A | 186 | 93 | 25.4 | 15.5 | 10.1 | 14.3 | 1/0 - 4/0 | |
| PPT-85R | N/A | 187 | 92 | 31.5 | 23.5 | 14.3 | 21.8 | 4/0-477 |
| Add | CATALOG | CFE SHORT DESCRIPTION | A | B | Ø1 | Ø2 | MIN RANGE | MAX RANGE | ACSR |
|---|---|---|---|---|---|---|---|---|---|
| PCT-44 | CRT 10 (1/0) | 345 | 171 | 20.7 | 11.3 | 9.3 | 10.1 | 8 - 1/0 | |
| PCT-61 | CRT 13 (3/0) | 403 | 200 | 25.4 | 15.5 | 11.9 | 14.3 | 4 - 4/0 | |
| PCT-70 | CRT 16 (266) | 403 | 200 | 30.4 | 20.5 | 14.9 | 16.3 | 4/0 - 266 | |
| PCT-80 | CRT 18 (336) | 450 | 224 | 30.4 | 20.5 | 16.9 | 18.8 | 4/0 - 336 | |
| PCT-90 | CRT 22 (477) | 518 | 258 | 31.5 | 23.5 | 20.1 | 22.4 | 4/0 - 477 |
| Add | CATALOG | CFE SHORT DESCRIPTION | A | B | C | MAIN RANGE | ACSR |
|---|---|---|---|---|---|---|---|
| PEA-518 | CDE 10 (1/0) | 194 | 73 | 94 | 8 - 14.30 | 2 - 4/0 | |
| PEA-518 | CDE 13 (3/0) | 194 | 73 | 94 | 8 - 14.30 | 2 - 4/0 | |
| PEA-922 | CDE 16 (266) | 244 | 102 | 107 | 16 - 21.8 | 266- 477 | |
| PEA-922 | CDE 18 (336) | 244 | 102 | 107 | 16 - 21.8 | 266- 477 | |
| PEA-922 | CDE 22 (477) | 244 | 102 | 107 | 16 - 22 | 266- 477 |
| Add | PARTALUM CATALOG | CFE SHORT DESCRIPTION | A | B | MAIN RANGE | AL-ACSR | TAP RANGE | AL-ACSR |
|---|---|---|---|---|---|---|---|---|
| PTAC-10-10 | CD99 9-12 / 14-8 | 108 | 45 | 9.3 - 12.8 | 2 - 3/0 | 4.1 - 8.0 | 8 -1/0 | |
| PTAC-40-40 | CD99 9-12 / 9-12 | 116 | 50 | 9.3 - 12.8 | 2 - 4/0 | 9.3 -12.8 | 2 - 4/0 | |
| PTAC-336-10 | CD99 14-22 / 14-8 | 145 | 64 | 14.9 -22.4 | 4/0-477 | 4.1 - 8.0 | 8 -1/0 | |
| PTAC-336-40 | CD99 14-22 / 9-12 | 145 | 69 | 14.9 -22.4 | 4/0-477 | 9.3 -12.8 | 2 - 4/0 | |
| PTAC-477-40 | CD99 14-22 / 14-22 | 145 | 115 | 14.9 -22.4 | 4/0-477 | 14.9 -22.4 | 4/0 - 477 |
| Add | CATALOG | CFE CAT. | A | B | C | D |
|---|---|---|---|---|---|---|
| PTM-2 | MET-16 | 41 | 24.5 | 19 | 25 |
| Add | CATALOG | CFE CAT. | A | B | C | D | GROUND ROD | CONDUCTOR DIAMETER RANGE |
|---|---|---|---|---|---|---|---|---|
| PTE-2 | CET-16 | 53 | 19 | 23 | 23 | 16 | 3.25 - 8.25 |
| Add | CATALOG | CFE CAT. | A | B | C | D | E | F | STRENGTH |
|---|---|---|---|---|---|---|---|---|---|
| GTE-111 | GA1 | 56 | 13 | 22 | 16 | 35 | 17 | 111 KN | |
| GTE-113 | GA2 | 71 | 14 | 22 | 16 | 39 | 17 | 133 KN |
| Add | CATALOG | CLASS | A | B | C | D |
|---|---|---|---|---|---|---|
| GABOLA-133 | 52-5 | 22 | 52 | 24 | 30 |
| Add | CATALOG | A | B | C | G | H | MECHANICAL STRENGTH KN |
|---|---|---|---|---|---|---|---|
| BOLA-133 | 57 | 24 | 129 | 17 | 71 | 133 |
| Add | CFE short description | D | A | B | C | E | F |
|---|---|---|---|---|---|---|---|
| DADO 46 RT | 165 | 175 | 171 | 84 | 41 | 47 | |
| DADO 47 RT | 190 | 200 | 196 | 90 | 47 | 53 |
NO RESULTS No products match your search. Adjust the text or clear the filters.
Applications
Where are distribution connectors and clamps used?
Partalum distribution connectors, clamps and fittings are used in distribution networks of up to 35 KV to connect and tap conductor with straight, pistol and suspension clamps, splice conductor via compression union, and ground conductor and structure with bronze and copper grounding terminals.
Network tapping
Straight, pistol and suspension clamps to connect and tap conductor in distribution networks of up to 35 KV.
Conductor splicing
Compression-type union to splice conductor and restore continuity of the distribution line.
Grounding
Bronze and copper grounding terminals, referenced to CFE, to ground conductor and structure.
Compression connection
Aluminum compression dies to crimp clamps and connectors with the corresponding tool.
Materials & standards
What are they made of and which standards do they meet?
Distribution connectors and clamps are made of aluminum and bronze for compression-type clamps and connectors, and of bronze and copper for the grounding terminals. The whole line is designed to conform with CFE specifications for distribution networks of up to 35 KV.



- Aluminum
- Bronze
- Copper
- CFE conformity
- Voltage ≤ 35 KV
FAQ
What engineering asks about this line.
What voltage level do Partalum distribution connectors and clamps cover?
They cover distribution networks of up to 35 KV, with compression-type clamps and connectors for connection, tapping, splicing and grounding.
What materials are the distribution clamps and connectors made of?
They are made of aluminum, bronze and copper: aluminum and bronze in compression-type clamps and connectors, and bronze and copper in the grounding terminals.
Quote
Need distribution connectors and clamps?
Tell us your description, conductor, voltage level and quantities. We reply with the right clamp or connector from the line.