MEXICAN MANUFACTURER SUBSTATION · TRANSMISSION · DISTRIBUTION CFE · NMX-ANCE

Applications

Applications

From the substation to the last tap, Partalum manufactures the connector or fitting for every point of the electrical grid. We cover four applications —substation, transmission lines, distribution networks and shield wire— in the range of 13.5 to 400 KV, to CFE specifications and NMX-ANCE standards.

13.5–400 KV 80–480 KN CFE · NMX-ANCE

Application map

Which product line corresponds to each application?

Each electrical application corresponds to one or more Partalum lines depending on its voltage range, its function and the project standard. This table relates the four applications to their KV range, their function and the product line.

Application × voltage range × function × product line.
ApplicationVoltage rangeFunctionProduct line
Substation 115–400 KV Bus, equipment and conductor connection Substation connectors (CS) · Substation assemblies (CSU)
Transmission lines 69–400 KV Suspension and tension strings, 1–4 C/F Transmission assemblies (CT) · Transmission fittings (HT)
Distribution networks ≤ 35 KV Clamps, taps and compression splices Distribution (DI)
Shield wire 69–400 KV Shield-wire suspension and dead-end; equipotential rings Transmission fittings (HT) · Transmission assemblies (CT)

The four applications

A connector or fitting for every point in the grid.

From the substation to the shield wire, each application has its voltage range, its function and the Partalum line that solves it.

01

Application · Substation

115–400 KV

What connectors and fittings are used in a high-voltage substation?

In a 115 to 400 KV substation, Partalum connectors and fittings join the rigid bus, the equipment and the conductor: compression terminal lugs with NEMA plate, aluminum IPS tube fittings to build the bus, insulator-base support, and connectors for autotransformer bushings. Suspension, tension and dead-end assemblies complete the connection inside the yard.

  • Connection of tubular aluminum IPS rigid bus (coupling, elbow, reducer, cap).
  • Conductor-to-equipment connection (breakers, disconnect switches, transformers) with NEMA 2N–8N terminal lugs.
  • Bus or conductor support on base insulator, at 3" and 5" heights.
  • Connection to autotransformer bushings with plain or threaded stud terminals.
  • 115–400 KV
  • NEMA 2N–8N
  • ACSR · ACSS · AS
  • IPS tube
  • Cu MCM
02

Application · Transmission lines

69–400 KV

What fittings are used in a 69 to 400 KV transmission line?

On 69 to 400 KV transmission lines, Partalum assemblies form the suspension and tension strings that hold the conductor at each structure, for bundles of 1 to 4 conductors per phase. String fittings —clevises, shackles, links, yokes, suspension clamps and compression dead-end clamps— transfer the conductor mechanical load to the tower, at ANSI insulator class 52.5 or 52.8.

  • Vertical or "V" suspension strings for bundles of 1 to 4 conductors per phase.
  • Tension and compression dead-end strings at deflection and terminal structures.
  • Hot-dip galvanized forged-steel string fittings, 80–480 KN.
  • Stockbridge dampers and yokes for bundle conductors.
  • 69–400 KV
  • ANSI class 52.5 or 52.8
  • 1–4 C/F
  • 80–480 KN
03

Application · Distribution networks

≤ 35 KV

What connectors are used in medium-voltage distribution networks?

In distribution networks of up to 35 KV, Partalum connectors resolve the joints and taps of the network in aluminum, bronze and copper: line clamps, tap connectors and compression splice joints. All parts are referenced to the CFE distribution catalog.

  • Line clamps for conductor support on pole and structure.
  • Tap connectors to run branches without cutting the main line.
  • Compression splice joints for conductor continuity.
  • Aluminum, bronze and copper depending on the conductor and the CFE reference.
  • ≤ 35 KV
  • Al · Br · Cu
  • Compression
  • CFE ref.
04

Application · Shield wire

69–400 KV

What fittings support the shield wire on a transmission line?

The shield wire (overhead ground wire) protects the transmission line against lightning strikes and is held by its own set of Partalum fittings: suspension and dead-end assemblies for shield wire, plus equipotential rings that control the potential gradient across the string. They are used in the same 69 to 400 KV range as the line they protect.

  • Shield-wire suspension assemblies at the top of the structure.
  • Shield-wire dead-end assemblies at tension and terminal structures.
  • Equipotential rings for gradient control across the string.
  • Clamps and splices specific to shield wire (AS / OPGW to be confirmed).
  • 69–400 KV
  • Shield wire
  • Equipotential ring
  • Forged steel

FAQ

What engineering asks about applications.

What electrical applications does Partalum manufacture connectors and fittings for?

For four applications: substations from 115 to 400 KV, transmission lines from 69 to 400 KV, distribution networks up to 35 KV and shield wire. Total coverage runs from 13.5 to 400 KV, to CFE specifications and NMX-ANCE standards.

Which product line corresponds to each application?

Substation uses substation connectors (CS) and substation assemblies (CSU); transmission and shield wire use transmission assemblies (CT) and transmission fittings (HT); distribution and grounding use the distribution line (DI) in aluminum, bronze and copper.

Quote

Does your application require a specific fitting?

Tell us the application, the conductor and the voltage level. We reply with the right line and fitting.

Download catalog